ElecGraph bridges EMT/RMS model simulation benchmarking, IEEE COMTRADE oscillography analytics, and AI-powered grid compliance into a unified, high-performance platform.
ElecGraph combines deep domain electrical engineering principles with advanced data science and automation to resolve critical grid challenges.
Model Under Test (MUT) benchmarking across IBR, Droop Control, Synchronous Machines, and FACTS in grid-connected and islanded topologies.
Explore SynchronizerUltra-fast ingestion and multi-channel oscillography analysis for IEEE C37.111 (.cfg/.dat) files and high-density CSV time-series.
Waveform AnalyticsAutomated neural network classification (Pass / Marginal / Fail) against dynamic performance criteria with explainable confidence metrics.
AI ClassificationDirect integration with SQL Server databases, automatic signal slot mapping, and one-click generation of comprehensive engineering reports.
Data IntegrationExperience how ElecGraph detects voltage sags, harmonic anomalies, and fault transients in real-time oscillograms.
Explore the specialized workspaces inside ElecGraph designed to simplify complex power system investigations.
The Simulation Synchronizer streamlines EMT (Electromagnetic Transient) and RMS modeling workflows. Engineers can rapidly stage multi-contingency tests against target generation models.
ElecGraph processes massive high-frequency digital fault records (DFR) and digital protective relay oscillograms with zero lag.
Eliminate manual curve-checking. ElecGraph uses specialized machine learning models trained on power system standards to validate compliance automatically.
ElecGraph is expanding towards physical hardware integration, connecting simulation test cases directly with real-time digital simulators and protection relays.
Four streamlined steps to execute comprehensive power system studies in minutes instead of weeks.
Configure your generator target model (IBR / Synchronous), line parameters, equivalent transformers, and POI boundary conditions.
Execute multi-scenario contingency sequences: 3-phase faults, frequency excursions, voltage sags, or islanded load-shedding transitions.
Load COMTRADE (.cfg/.dat) or CSV datasets, measure delta cursors, isolate harmonic spikes, and review synchronized multi-channel plots.
Run AI compliance scoring (Pass / Warning / Fail) and generate automated, publication-ready PDF and Word engineering reports instantly.
Download the free Community Edition or schedule a 1-on-1 technical consultation with ElectroMertic software architects.
Answers to technical, operational, and commercial questions about ElecGraph.